the electrical state of equipment. The different values of this attribute are
used to distinguish electrical equipment with allocated functional item, electrical
equipment that has no functional item allocated, and placeholders for empty positions
on
panels, etc. Functional items are also known as reference designators. The attribute
equipState can have one of the following values:
- "active" - for electrical
equipment, which is installed in one of the systems circuits and has a functional
item
allocated
- "notactiv" - for electrical equipment, which is not active in one of the
systems circuits. A not active electrical equipment is used as a placeholder, where
for
example no component is installed in a position of a circuit breaker panel
-
"logequip" - for electrical equipment, which is installed in one of the systems circuits
and has no functional item allocated